QSK50 for Data Center Continuous (DCC) Rating

Frequency

50, 60 Hz

Rated for kW kVA
Prime 1020 - 1365 1275 - 1706
Standby 1120 - 1500 1400 - 1875
Continuous 820 - 1140 1025 - 1425
Data Center Continuous 1020 - 1365 1275 - 1706

Certification

N/A

Product Availability

Africa Middle East, Asia Pacific, Europe, India, Latin America, North America

Select an application

dqgan generator

Cummins® commercial generator sets are fully integrated power generation systems providing optimum performance, reliability and versatility for Data Center applications.

Features & Benefits

Data Center Continuous (DCC) - Applicable for supplying power continuously to a constant or varying electrical load for unlimited hours in a data center application.

Uptime Compliant - Meets the requirement of a Tier III and IV data center site by being rated to run for unlimited hours of operation when loaded to 'N' demand for the engine generator set.

Cummins heavy-duty engine - Rugged 4- cycle, industrial diesel delivers reliable power, low emissions and fast response to load changes.

Alternator - Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings, low waveform distortion with non-linear loads and fault clearing short-circuit capability.

Permanent Magnet Generator (PMG) - Offers enhanced motor starting and fault clearing short circuit capability.

Control system - The PowerCommand® digital control is standard equipment and provides total genset system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, AmpSentryTM protective relay, output metering

and auto-shutdown at fault detection and NFPA 110 Level 1 compliance.

Cooling system - Standard and enhanced integral set-mounted radiator systems, designed and tested for rated ambient temperatures, simplifies facility design requirements for rejected heat.

NFPA - The genset accepts full rated load in a single step in accordance with NFPA 110 for Level 1 systems.

Warranty and service - Backed by a comprehensive warranty and worldwide distributor network.

Specifications

Bore: 159 mm (6.25 in.)

Stroke: 159 mm (6.25 in.)

Displacement: 50.3 litres (3067 in3)

Configuration: Cast iron, V 16 cylinder

Battery capacity: 1800 amps minimum at ambient temperature of 0 °C (32 °F)

Battery charging alternator: 55 amps

Starting voltage: 24 volts, negative ground

Fuel system: Cummins’ modular common rail system

Fuel filter: Two stage spin-on fuel filter and water separator system. Stage 1 has a three element 7 micron filter and stage 2 has a three element 3 micron filter.

Air cleaner type: Dry replaceable element

Lube oil filter type(s): Four spin-on, combination full flow filter and bypass filters

Standard cooling system: High ambient cooling system

generator model
Spec Sheet
Hz
Prime kW / kVA
Standby kW / kVA
Continuous kW / kVA
Data Center Continuous kW / kVA
fuel type
engine model
rating
cert
60
1135 / 1419
60
1365 / 1706
50
1232 / 1540
DQGAH
50
1120 / 1400
DQGAJ
50
1232 / 1540
DQGAK
50
1120 / 1400
50
1320 / 1650
50
1020 / 1275
50
1020 / 1275
1120 / 1400
820 / 1025
1020 / 1275
Diesel
QSK50-G4 NR2
Continuous, Data Center Continuous, Prime, Standby
E.U., mobile application, E.U., stationary application, EPA, nonroad (portable) application, EPA, stationary emergency application, EPA, stationary non-emergency application
60
1135 / 1419
1250 / 1563
1000 / 1250
1135 / 1419
Diesel
QSK50-G5 NR2
Continuous, Data Center Continuous, Prime, Standby
E.U., mobile application, E.U., stationary application, EPA, nonroad (portable) application, EPA, stationary emergency application, EPA, stationary non-emergency application
50
1232 / 1540
1360 / 1700
1000 / 1250
1232 / 1540
Diesel
QSK50-G4 NR2
Continuous, Data Center Continuous, Prime, Standby
E.U., mobile application, E.U., stationary application, EPA, nonroad (portable) application, EPA, stationary emergency application, EPA, stationary non-emergency application
60
1365 / 1706
1500 / 1875
1100 / 1375
1365 / 1706
Diesel
QSK50-G5 NR2
Continuous, Data Center Continuous, Prime, Standby
E.U., mobile application, E.U., stationary application, EPA, nonroad (portable) application, EPA, stationary emergency application, EPA, stationary non-emergency application
50
1320 / 1650
1460 / 1825
1140 / 1425
1320 / 1650
Diesel
QSK50-G7 NR2
Continuous, Data Center Continuous, Prime, Standby
E.U., mobile application, E.U., stationary application, EPA, nonroad (portable) application, EPA, stationary emergency application, EPA, stationary non-emergency application
60
Diesel
QSK50
Standby, Prime, Continuous, Data Center Continuous
U.S. EPA, Stationary Emergency Application; Outside of U.S. and E.U. Application
60
Diesel
QSK50
Standby, Prime, Continuous, Data Center Continuous
U.S. EPA, Stationary Emergency Application; Outside of U.S. and E.U. Application


To access our complete brochure library, click here.
Generator Models

Frequency (Hz)

50

Fuel Type

Diesel

Prime

1020 kW

1275 kVA

Standby

1120 kW

1400 kVA

Frequency (Hz)

60

Fuel Type

Diesel

Prime

1135 kW

1419 kVA

Standby

1250 kW

1563 kVA

Frequency (Hz)

50

Fuel Type

Diesel

Prime

1232 kW

1540 kVA

Standby

1360 kW

1700 kVA

Frequency (Hz)

60

Fuel Type

Diesel

Prime

1365 kW

1706 kVA

Standby

1500 kW

1875 kVA

Frequency (Hz)

50

Fuel Type

Diesel

Prime

1320 kW

1650 kVA

Standby

1460 kW

1825 kVA

Frequency (Hz)

60

Fuel Type

Diesel

Frequency (Hz)

60

Fuel Type

Diesel