6BTA5.9 for Commercial Industrial

Frequency

50, 60 Hz

Rated for kW kVA
Prime 65 - 124 82 - 155
Standby 72 - 145 90 - 181
Continuous 77 96

Certification

EPA Tier 1

Product Availability

Africa Middle East, Asia Pacific, Europe, India, Latin America, North America

Applications

Commercial Industrial
6bta5.9 generator
Specifications
  • Cummins® heavy-duty engine - Rugged 4-cycle, industrial diesel delivers reliable power, low emissions and fast response to load changes.
  • Alternator - Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings, low waveform distortion with non-linear loads and fault clearing short-circuit capability.
  • Control system - The PowerCommand® electronic control is standard equipment and provides total genset system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, AmpSentry™ protection, output metering, auto-shutdown at fault detection and NFPA 110 Level 1 compliance.
  • Cooling system - Standard integral set-mounted radiator system, designed and tested for rated ambient temperatures, simplifies facility design requirements for rejected heat.
  • Enclosures - Optional weather protective and sound attenuated enclosures are available.
  • Fuel tanks - Dual wall sub-base fuel tanks and in-skid day tanks are also offered.
  • NFPA - The genset accepts full rated load in a single step in accordance with NFPA 110 for Level 1 systems.
  • Warranty
generator model
Spec Sheet
Hz
Prime kW / kVA
Standby kW / kVA
Continuous kW / kVA
fuel type
engine model
rating
cert
C100 D6
60
91 / 114
100 / 125
Diesel
C110 D5
50
80 / 100
88 / 110
Diesel
C110 D5
50
80 / 100
88 / 110
Diesel
C135 D6
60
122 / 153
135 / 169
Diesel
60
124 / 155
136 / 170
Diesel
EPA Tier 1
60
145 / 181
Diesel
C150 D5
50
109 / 136
120 / 150
Diesel
EPA Tier 1
C150 D5
50
109 / 136
120 / 150
Diesel
C80 D6
60
72 / 90
80 / 100
Diesel
C90 D5
50
65 / 82
72 / 90
Diesel
DGDB
60
90 / 113
100 / 125
Diesel
EPA Tier 1
DGDK
50
90 / 113
100 / 125
Diesel
DGDK
60
113 / 141
125 / 156
Diesel
EPA Tier 1
60
123 / 153
135 / 169
Diesel
6BTAA5.9-G6
Prime, Standby
E.U., mobile application, E.U., stationary application, EPA, nonroad (portable) application, EPA, stationary emergency application, EPA, stationary non-emergency application
60
124 / 155
136 / 170
77 / 96
Diesel
6BTA5.9-G3
Continuous, Prime, Standby
E.U., mobile application, E.U., stationary application, EPA, nonroad (portable) application, EPA, stationary emergency application, EPA, stationary non-emergency application
60
145 / 181
Diesel
6BTA5.9-G2
Standby
E.U., mobile application, E.U., stationary application, EPA, nonroad (portable) application, EPA, stationary emergency application, EPA, stationary non-emergency application


To access our complete brochure library, click here.
Generator Models

Frequency (Hz)

60

Fuel Type

Diesel

Prime

123 kW

153 kVA

Standby

135 kW

169 kVA

Frequency (Hz)

60

Fuel Type

Diesel

Prime

124 kW

155 kVA

Standby

136 kW

170 kVA

Frequency (Hz)

60

Fuel Type

Diesel

Standby

145 kW

181 kVA

Redirecting to